Skip to main content Scroll Top

Clamp Meter True RMS AC/DC 2500A 1000V – UNI-T UT222

Clamp Meter True RMS AC/DC 2500A 1000V – UNI-T UT222

Original price was: R9257,50.Current price is: R6399,00.

The UNI-T UT222 is an ultra-high-capacity, professional-grade digital clamp meter engineered for heavy-duty industrial diagnostics and utility maintenance. Boasting a massive 2500A AC/DC current range and an oversized 63mm jaw, this 6000-count True RMS instrument is the definitive tool for auditing large-scale busbars and high-power conductors. Featuring specialized Inrush Current capture, a low-pass filter for frequency drive analysis, and a safety rating of CAT IV 600V / CAT III 1000V, the UT222 provides laboratory-grade precision for the most demanding high-energy environments.

🇿🇦 Free Shipping nationwide
South Africa only
SKU: UT222
Share:
Description
Additional Info
Reviews
Description

High-Power Diagnostic Authority

The UNI-T UT222 represents the industrial pinnacle of the UNI-T clamp meter range, designed specifically for technicians who work with high-current primary distribution and heavy machinery. In industrial landscapes where standard 1000A meters reach their limit, the UT222 provides the necessary overhead to safely and accurately monitor systems up to 2500A. Its specialized circuitry is optimized to deliver stable readings even in the presence of massive electromagnetic interference.

Massive Capacity and Mechanical Precision

The engineering of the UT222 is centered around the management of large conductors:

  • 2500A AC/DC Measurement: The high-capacity Hall-effect sensor allows for the non-invasive auditing of both AC and DC loads, essential for massive battery banks, heavy-duty DC motors, and primary utility feeders.

  • 63mm Oversized Jaw Opening: The massive aperture is designed to encompass the thickest industrial cables and parallel conductor bundles, ensuring that technicians do not have to struggle with restricted jaw clearance.

  • True RMS Accuracy: Industrial loads are often non-linear. The True RMS technology in the UT222 ensures that current and voltage data remain accurate regardless of waveform distortion from industrial frequency converters.

Professional Motor and Power Diagnostics

The UT222 is equipped with advanced analytical modes for deep system characterization:

  • Inrush Current Mode: This feature captures the instantaneous peak current when heavy industrial motors or transformers are energized. This is critical for sizing protective devices and evaluating the health of high-torque starter systems.

  • Low-Pass Filter (LPF): Specialized filtering blocks high-frequency noise generated by Variable Frequency Drives (VFDs), allowing for the accurate measurement of the fundamental voltage and frequency that the equipment is actually receiving.

  • Simultaneous Measurement: The dual-display capability allows for the tracking of voltage and frequency or current and frequency at the same time, providing a comprehensive view of system stability at a glance.

Industrial Build and Safety Standards

Designed for the rigors of field service, the UT222 features a ruggedized, double-injection housing and a tactile rotary dial optimized for one-handed operation. The high-contrast backlit LCD is paired with a high-intensity LED flashlight for safe work in dark distribution galleries. With its CAT IV 600V safety certification, it is fully equipped for use at the source of low-voltage installations, ensuring maximum protection for the operator during high-energy auditing.

Key Features & Technical Advantages:

  • 2500A AC/DC Current Range: Extreme-duty capacity for industrial and utility loads.

  • 63mm Large Jaw Opening: Optimized for thick busbars and high-gauge multi-conductors.

  • Inrush Current Capture: Precision tracking of motor and transformer startup transients.

  • True RMS & LPF: High-accuracy diagnostics in electronically noisy VFD environments.

  • 1000V AC/DC Measurement: Professional-tier voltage auditing for primary panels.

  • High-Resolution 6000-Count Display: Fine increments for professional-grade data monitoring.

Professional Application Scenarios

  • Mining & Heavy Manufacturing: Monitoring the load on massive conveyor motors and industrial crushers.

  • Utility Substation Auditing: Balancing high-current phases on primary distribution busbars.

  • Renewable Energy Infrastructure: Auditing high-capacity DC outputs from commercial solar inverter banks.

  • Railway & Marine Maintenance: Troubleshooting high-current DC traction systems and shipboard power distribution.

  • Telecommunications Power Plants: Verifying the health of massive UPS systems and high-current battery chargers.

Maintenance and Best Practices

To maintain the professional accuracy and longevity of your UNI-T UT222, follow these protocols:

  • Zero Calibration: Always use the Relative (REL/ZERO) button before performing DC current measurements to negate the effects of ambient magnetic fields.

  • Jaw Hygiene: Keep the 63mm jaw faces free of dust and metallic particles; even a microscopic gap in the magnetic circuit can result in significant current errors at 2500A.

  • Battery Management: The high-capacity Hall-effect sensor and backlight consume power; replace the 9V battery immediately when the low-power indicator appears to maintain calibration accuracy.

  • High-Energy Lead Safety: Periodically inspect the high-voltage rated test leads for insulation fatigue near the handles and probe tips.

Additional Info
Reviews

Reviews

There are no reviews yet.

Add a review

Item added to cart View Cart Checkout
Item added to wishlist View Wishlist
Item removed from wishlist